Water Softener Overflow Drain

Water overflows a faulty brine valve assembly or damaged rotor valve can cause the salt tank to overflow.
Water softener overflow drain. Certifications are one area where you can always count on the fleck water softeners to deliver. You can dump the water out of your water softener down a drain as it doesn t pose an environmental hazard. Tapworks water softener tips for fitting the drain and overflow hose the hose needs to enter an air gap current water regulations is 20mm. The brine valve assembly should shut off water flowing into the salt tank when brine water reaches the correct level.
First the softener had water overflow issues because the overflow elbow in the brine tank did not have a drain tube connecting it to the floor drain. Both of these overflows are 3 8 clear flexible hose. One of the requirements of the water softener is a drain for a valve overflow and a salt storage tank overflow. This is to prevent non potable water from flowing backwards possibly mixing and contaminating potable drinking water.
Before you attempt this you will need to remove the brine well. The econominder 5600 is tested by ansi nsf standard 372 to prove its lead free compliance. This is the long cylinder that holds the safety float inside your brine tank. Ejector pump failure if your water softener drains into a sump pump or ejector pump used to remove that wastewater from the building an ejector pump failure can cause softener overflow and leaks see sump pumps home for a series of ejector pump or sump pump diagnosis and repair articles.
The hose outputs are located about 30 and 40 above floor level respectively. Take care that the drain will not freeze. Replace the brine valve assembly if it doesn t shut off fill water causing brine water to overflow the tank. A water softeners salt tank will overflow when the systems brine water float shut off assembly fails to shut off the water feed and one or both of two other things happen.
The system either did not remove all the brine from the tank before refilling it or the system continued to add water to the tank beyond the correct level. According to most plumbing codes a water softener drain line must not be connected directly to the household waste system. Standard square brine tank safety float overflow drain valve 1 noryl plastic bypass warranty. By code water softeners must be emptied into a laundry sink floor drain sump hole or properly trapped special outlet preserving an air gap of at least two times the diameter of the drain line but in no case less than 1 1 2 above the top of the.